path: "p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
locale: en-gb
alternates:
    nl-nl: "https://www.estg.eu/nl-nl/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    en-gb: "https://www.estg.eu/en-gb/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    x-default: "https://www.estg.eu/en-gb/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    pl-pl: "https://www.estg.eu/pl-pl/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    de-de: "https://www.estg.eu/de-de/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    fr-fr: "https://www.estg.eu/fr-fr/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    it-it: "https://www.estg.eu/it-it/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"
    sv-se: "https://www.estg.eu/sv-se/p/GW-200.0130200/growatt-max-125ktl3-x-lv-afci"

title: "Growatt MAX 125KTL3-X LV (AFCI)"
description: "Growatt MAX 125KTL3-X LV (AFCI)  | One-Stop-Shop | +50 A-brands | Exclusively for Professionals"

type: product_page

---

# Growatt Inverter 3PH MAX 125KTL3-X LV (AFCI) - Art.No.: GW-200.0130200

## Specifications

- **Brand**: Growatt
- **HS code**: 85044084
- **Manufactor**: Growatt
- **Net Height**: 640 MILLIMETER
- **Net Length**: 345 MILLIMETER
- **Net Weight**: 84 KILOGRAM
- **Net Width**: 970 MILLIMETER
- **Origin**: China
- **Arc-fault circuit interrupter**: Yes
- **Communication**: RS485
- **Display**: Yes
- **Ingress Protection**: IP66
- **Max. output apparent power**: 137500 VOLTAMPERE
- **Max. output current**: 198.5 AMPERE
- **Max. output power**: 125000 WATT
- **Number of MPPT**: 10
- **Number of phases**: 3 phase
- **System**: Growatt MAX series
- **Type**: String
- **Warranty in Years**: 5

### MULTIPLE MPPTS DESIGN


2 strings per MPP tracker, each MPP tracker can achieve its best performance, more energy yields of whole system.


### COMPATIBLE WITH HIGH POWER MODULES


String current up to 16A, MPPT current 32A, best match high power modules and bi-facial modules.


### KEY FEATURES


**High Yields**


- Multiple MPPTs design, up to 10 MPPTs
- Compatible with high power modules
- DC/AC ratio up to 1.5


**Safety and Reliability**


- AFCI protection optional
- Type II SPD on DC and AC sides
- IP 66 protection degree


**Optimal Electricity Cost**


- Compatible with AI and Cu AC cables
- DC 2 in 1 connection
- PLC communication optional

## Downloads

- [MAX100 125KTL3 X LV 1 ](https://cdn.estg.eu/p/4/5/9/f/459f4738860207970f27684ba913938d4f465665_MAX100_125KTL3_X_LV_1_.pdf)
- [GROWATT ENERGY STORAGE CONFIGURATION QUICK CHECK LIST](https://cdn.estg.eu/p/6/b/e/4/6be4ae876d6f8fe2042e1afa188e1aafc4f54d9d_GROWATT_ENERGY_STORAGE_CONFIGURATION_QUICK_CHECK_LIST.pdf)
- [MAX 100 150KTL3 X LV MV Quick Guide EN 202203](https://cdn.estg.eu/p/2/3/b/d/23bd36dc4498b8be4a9df4452d7d8e47e487880a_MAX_100_150KTL3_X_LV_MV_Quick_Guide_EN_202203.pdf)
- [MAX 100 150KTL3 X LV MV User Manual EN 202203](https://cdn.estg.eu/p/3/8/8/6/388670294fc77d59c299ee5e0d60b817988e6a63_MAX_100_150KTL3_X_LV_MV_User_Manual_EN_202203.pdf)
- [MAX 100 125KTL3 X LV C10 C11](https://cdn.estg.eu/p/d/1/d/9/d1d9a53ffba6c445bcf5e1aa90335f59b76e515e_MAX_100_125KTL3_X_LV_C10_C11.pdf)
- [MAX 100 125KTL3 X LV CEI 0 16](https://cdn.estg.eu/p/8/f/4/9/8f49f581edb63d6235cf54d5615362db7e6e226f_MAX_100_125KTL3_X_LV_CEI_0_16.pdf)
- [MAX 100 125KTL3 X LV CEI 0 21](https://cdn.estg.eu/p/7/6/f/c/76fc1574df5fc185aec4f5f87c32b6c1a8de9d32_MAX_100_125KTL3_X_LV_CEI_0_21.pdf)