SolarEdge 3PH Inverter, 25kW, Glands, DC safety unit with switch, AC & DC SPD, Fuses, RSD

product.article_number
20% Extra Discount

SolarEdge 3PH Inverter, 25kW, Glands, DC safety unit with switch, AC & DC SPD, Fuses, RSD

product.article_number
product.accordion_title
product.tabs.description

SolarEdge 3PH Omvormer, 25kW, Glens, DC safety unit met switch, AC & DC SPD, Fuses, RSD, met SetApp configuratie (SE25K-RWR0IBNZ4) is a three-phase commercial inverter with connection glands to connect the DC cabling. It does not have MC4 connectors.

The inverter is also equipped with a type 2 DC overvoltage protection and a Surge Protection Device (SPD). In terms of communication, two RS485 ports and one Ethernet connection are integrated. It is possible to connect to the inverter via wifi. However, a separate antenna is required for this. The SolarEdge SetApp can then be used for commissioning and monitoring.

Communication

A connection via RS485 is possible via two ports which are standard in the inverter. There is also an Ethernet port. It is possible to use a wi-fi network, but this requires a separate antenna.

Security

Arc protection, leakage current and overvoltage protection are all present. Electric arcs are not uncommon. For example, they occur during normal use of switches and plugs. Arcs that take on certain proportions, for example due to defects, can be harmful or even result in fire. Leakage currents also occur. Often these are innocent and are disposed of without any problems. If a person comes into contact with a certain component that experiences leakage currents, this can result in dangerous situations. The leakage current protection ensures that the system switches itself off within 20 to 40ms as soon as a person comes into contact with the circuit. This prevents electrocution.

DC safety unit with switch

The supplied DC safety unit with switch is located underneath the inverter. This switch is a two-pole DC switch. This ensures that both the neutral and the phase wire are interrupted, so that the entire system will be free of power. The SPD will protect the system against overvoltage caused by lightning strikes, for example.

See all our SolarEdge inverters


product.tabs.specifications
Brand
SolarEdge
HS code
85044086
Manufactor
SolarEdge
Net Height
775 mm
Net Length
260 mm
Net Weight
48 kg
Net Width
315 mm
Origin
Israel
Ingress Protection
IP65
Max. output power
25000 W
Number of phases
3 phase
Warranty in Years
12